Section 4. IEC 62443-4-2
It is necessary to comply with IEC 62443-4-1 for approval of IEC 62443-4-2.
IEC 6244-4-2 – Certifies individual components (hardware, software, devices, embedded systems)
- Selecting the desired security level (SL).
- Safety testing at an accredited laboratory: An accredited laboratory runs tests on the component to validate compliance with the 7 fundamental requirements (FR).
- Certification by a Certification Body (CB): If the laboratory confirms that the component complies with the standard, the CB issues IEC 62443-4-2 certification.
¿How?
- Functional security tests.
- Pentesting and Fuzzing.
- This verifies the implementation of security controls.
The technical requirements for systems (IEC 62443-3-3) and products (IEC 62443-4-2) are evaluated in the standard by 4 Safety Levels (SL).
Levels indicate resistance against different classes of attackers.
Each of the seven defined FRs has four SLs defined, and the component is certified against an SL.

Depending on the type of product defined in the standard, there are complementary requirements of security.